Vacuum pressure casting machine with Sweep Mode Vibration Technology and innovative feeding system
The absolute „State of the art“-machine: the VC 680 V garantuees highest efficiency – due to a maximum of rapidness and quality.
The Vacuum Pressure Casting Machine VC 680 V is based on the VC 650 V. However, the filling device provided as standard means there is no need to open the melting chamber for refilling. This way, the melting chamber temperature remains high and unnecessary loss of energy is avoided. Most importantly: No oxygen enters the melting chamber so the chamber does not need to be evacuated again and refilled with inert gas.
The advantages:
- lower personnel costs
- more consistent casting quality
- better process stability, less waste
- optimised overlapping casting
- up to 20 casting cycles per hour
- high energy efficiency
- longer service lives for consumables
- minimised metal loss
- replenishment without loss of pressure
The VC 680 V ist also available als HTC version with a max. temperature of 2,000° C.
Data Overview of VC680V
■ standard equipment, ○ optional, - not availableVC400 | VC450 | VC500 | VC460V | VC480V | VC650V | VC680V | VC1000V | VC25000 | VC3000V | VC680VHTC | VC1000VHTC | VC12000HTC | VC3000VHTC | |
Power
|
||||||||||||||
Power max. / electrical connection | 3.5 kW (230 V)|4.5 kW (3x400 V) | 4,5 kW (3x400 V) | 10 kW (3x400 V)|10 kW(3x208 V) | 4,5 kW (3x400 V) | 8 kW (3x400 V) | 12 kW (3x400v) | 12 kW (3x400v) | 20 kW (3x400 V) | 60 kW (3x400 V) | 30 kW (3x400 V) | 12 kW (3x400v) | 20 kW (3x400 V) | 40-60 kW (3x400 V) | 30 kW (3x400 V) |
Temperature max. | 1400° C | 1600° C | ||||||||||||
Temperature max. indirect inductive heating HTC | 1850° C | 1850° C | 1850° C | 1850° C | 2000° C | 2000° C | 1850° C | 2000° C | ||||||
Capacity
|
||||||||||||||
Crucible Volume | ■ 170 ccm = 2,5 kg Au 18 ct / 1,5 kg Cu* | 170 ccm = 2,5 kg Au 18 ct / 1,5 kg Cu* | ■ 245 ccm = 3,6 kg Au 18 ct / 2 kg Cu* ○ 386 ccm = 5,8 kg Au 18 ct / 3,3 kg Cu* |
170 ccm = 2,5 kg Au 18 ct / 1,5 kg Cu* | ■ 170 ccm = 2,5 kg Au 18 ct / 1,5 kg Cu* ○ 245 ccm = 3,6 kg Au 18 ct / 2 kg Cu* |
■ 245 ccm = 3,6 kg Au 18 ct / 2 kg Cu* ○ 386 ccm = 5,8 kg Au 18 ct / 3,3 kg Cu* ○ 700 ccm =10,5 kg Au 18 ct / 6 kg Cu* |
■ 245 ccm = 3,6 kg Au 18 ct / 2 kg Cu* ○ 386 ccm = 5,8 kg Au 18 ct / 3,3 kg Cu* ○ 700 ccm =10,5 kg Au 18 ct / 6 kg Cu* |
1,5 l (1,7) = 4 kg Al / 12 kg Cu / 12 kg steel* | 25 l = 65 kg Al / 200 kg Cu* | 3,4 l (3,9) = 8,5 kg Al / 25 kg Cu / 25 kg steel* | ■ 245 ccm = 3,6 kg Au 18 ct / 2 kg Cu* ○ 386 ccm = 5,8 kg Au 18 ct / 3,3 kg Cu* ○ 700 ccm =10,5 kg Au 18 ct / 6 kg Cu* |
1,5 l (1,7) = 4 kg Al / 12 kg Cu / 12 kg steel* | 12 l (14 ) = 30 kg Al / 90 kg Cu / 90 kg steel* | 3,4 l (3,9) = 8,5 kg Al / 25 kg Cu / 25 kg steel* |
For use of molds up to | ø 130 mm / 240 mm h | ■ ø 130 mm / 240 mm h ○ ø 160 mm / 400 mm h |
■ ø 130 mm / 240 mm h ○ ø 160 mm / 400 mm h |
■ ø 130 mm / 240 mm h ○ ø 160 mm / 400 mm h |
■ ø 130 mm / 240 mm h ○ ø 160 mm / 400 mm h |
ø 250 mm / 500 mm h | ø 600 mm / 800 mm h | ø 450 mm / 600 mm h | ■ ø 130 mm / 240 mm h ○ ø 160 mm / 400 mm h |
ø 250 mm / 500 mm h | ø 600 mm / 800 mm h | ø 450 mm / 600 mm h | ||
For use of molds | up to ø 130 mm / 240 mm h | ■ up to ø 130 mm / 240 mm h ○ bis ø 160 mm / 400 mm h | ||||||||||||
Operation and Control
|
||||||||||||||
Maximum pressure | ■ up to 1,5 bar ○ up to 3,0 bar | ■ up to 1,5 bar ○ up to 3,0 bar | ■ up to 1,5 bar ○ up to 3,0 bar | ■ up to 1,5 bar ○ up to 3,0 bar | ■ up to 1,5 bar ○ up to 3,0 bar | 3 bar | 3 bar | 0,5 bar | 0,3 bar | 0,3 bar | 3 bar | 0,5 bar | 0,3 bar | 0,3 bar |
Automatic mold and chamber lift | ■ | - | ■ | - | ■ | ■ | ■ | ■ | ||||||
Control system | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout |
Automatic bell lock | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ |
Dual temperature control | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ■ | ■ | ■ | ○ | ■ | ■ | ■ |
Turbo Pressure Function | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ |
Mold temperature measurement | - | - | - | ■ | ■ | ■ | ||||||||
HSC (High Speed Casting) feature | ○ | ○ | ○ | ○ | ○ | ○ | ||||||||
Turbo Pressure PLUS system | - | - | ○ | ■ | ■ | ■ | ||||||||
Vibration technology | - | - | ■ | standard equipment Sweep Mode | standard equipment Sweep Mode | ■ | ■ | ■ | standard equipment Sweep Mode | ■ | ■ | ■ | ||
Automatic mold and chamber lift | ■ | ■ | ■ | ■ | ■ | ■ | - | ■ | ■ | ■ | - | ■ | ||
Automatic feeding system w/ autom. sealing rod | - | - | - | - | ■ | ■ | ||||||||
Automatic closing system | - | - | - | ■ | ■ | ■ | ||||||||
Programs | 20 | 20 | 20 | 20 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
Mold temperature measurement | ■ | ■ | ||||||||||||
Temp. measurement by optical pyrometer | 1400° C | 1400° C | 1600° C | 1700° C | 1700° C | 1500° C | 1300° C | 1500° C | 1700° C | 1500° C | 1300° C | 1500° C | ||
Turbulence reduction software | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ |
Quality Assurance
|
||||||||||||||
RS 232, Ethernet, USB interface, diagnostic system | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ |
Data printer | - | ○ | - | ○ | ○ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ |
GSM-modem for remote service | ○ | ○ | ○ | ○ | ○ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ |
DMS
|
■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ | ■ |
InduthermCloud | ○ | ○ | ○ | ○ | ○ | ○ | ■ | ○ | ○ | ○ | ■ | ○ | ○ | ○ |
iThermControl | ○ | ○ | ○ | ○ | ○ | ○ | ■ | ■ | ||||||
Accesories
|
||||||||||||||
Sintering / diffusion bonding kit | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ||||||
Granulation tank | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
Granulation tank with flake option | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
Vacuum pump | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
Water chiller | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
Also available as granulating unit | - | GU 500 |
* Liquid metal up to top level of the crucible
** with additional gas tank for Turbo pressure PLUS
All machine descriptions and technical data published on this site make no claim to be complete. They are subject to change and therefore they are not basis of contract.